What the data shows
Short write-ups of findings from our open data studies and our own runs. Every post links to the study page, table or record its numbers came from, and each of those can be downloaded. For longer pieces, see Research and the Data Atlas.
Four calculations called our candidate unstable. Labs had already made it.
Lithium hafnate (Li2HfO3) was on our candidate list. Four phonon calculations, not all judged by the same rule, called its crystal unstable; then we found six papers describing lab-made samples, the first from 1969. Here is what we checked, what we got wrong, and what we changed.
What “not in the databases” does and doesn’t mean
When we say a candidate compound is not in the Materials Project or the Crystallography Open Database, we mean exactly that and no more. It starts a novelty check; it does not finish one.
Why we keep a record of our dead ends
Many negative results are never published, so teams repeat each other's dead ends. We keep a record of the ones our own pipelines turn up, each with a grade for how far to trust it.
136 of 154: most entries passing one optical-permittivity cut on the Materials Project DFPT set have computed gaps under 1 eV
On the Materials Project DFPT dielectric set, 136 of 154 entries that pass an optical-only high-k screen have a computed band gap under 1 eV, and it catches fewer of the entries meeting our high-k-insulator rule than a random pick of the same size would on average, a gap too small, on 46 entries, to read much into. On JARVIS-DFT it catches far fewer than a random pick would, though there its screen and rule read different quantities, which could cause some of the gap, and we ran no formal test.
One in six: how often open DFT databases disagree on whether a compound is stable
We compared 62,803 compositions across Materials Project, JARVIS-DFT, AFLOW and OQMD. For 17–18% of shared compounds, two databases disagree on whether the compound sits on the convex hull.
DFT band gaps run about 30% low, and the miss grows with the gap
We matched 1,120 semiconductors and insulators with measured band gaps to Materials Project, JARVIS-DFT and AFLOW. The databases underestimate the measured gap in 86–87% of cases.
120 of 729: how few lithium solid electrolytes clear 1 mS/cm at room temperature
We merged 1,127 measured room-temperature conductivities for 729 lithium solid electrolytes. Only 120 compositions reach the 1 mS/cm mark, and most of them are sulfides.